Hello Guest

Sign in / Register

Welcome,{$name}!

/ Logout
English
EnglishDeutschItaliaFrançais한국의русскийSvenskaNederlandespañolPortuguêspolski繁体中文SuomiGaeilgeSlovenskáSlovenijaČeštinaMelayuMagyarországHrvatskaDanskromânescIndonesiaΕλλάδαБългарски езикGalegolietuviųMaoriRepublika e ShqipërisëالعربيةአማርኛAzərbaycanEesti VabariikEuskeraБеларусьLëtzebuergeschAyitiAfrikaansBosnaíslenskaCambodiaမြန်မာМонголулсМакедонскиmalaɡasʲພາສາລາວKurdîსაქართველოIsiXhosaفارسیisiZuluPilipinoසිංහලTürk diliTiếng ViệtहिंदीТоҷикӣاردوภาษาไทยO'zbekKongeriketবাংলা ভাষারChicheŵaSamoaSesothoCрпскиKiswahiliУкраїнаनेपालीעִבְרִיתپښتوКыргыз тилиҚазақшаCatalàCorsaLatviešuHausaગુજરાતીಕನ್ನಡkannaḍaमराठी
Vicor Corporation
VI-2TZ-EX Image

View larger Image

Image may be representation.
See specs for product details.

VI-2TZ-EX

Manufacturer Part Number: VI-2TZ-EX
Manufacturer/Brand: Vicor Corporation
Part of Description: DC DC CONVERTER 2V 15W
Datasheets: 1.VI-2TZ-EX.pdf 2.VI-2TZ-EX.pdf 3.VI-2TZ-EX.pdf
RoHs Status: Lead free / RoHS Compliant
Stock Condition: 45115 pcs Stock
Ship From: Hong Kong
Shipment Way: DHL/Fedex/TNT/UPS/EMS

Request Quote

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@Y-IC.com.

Part No.
Quantity
Target Price(USD)

Inquiry Online

  • Contact Name
  • Company
  • E-mail
  • Phone
  • Message
  • Verify
  • Specifications
  • QC & Packaging
  • Shipping
  • Payment

QC (Quality Warranty)

All products are carefully inspected before shipment according to our Quality Management practices. We ensure each part is genuine, meets specification requirements, and is functionally checked against original datasheets.
Our quality process supports reliable part performance and minimized risk of defects in customer applications.

Visual Inspection X-Ray Analysis Decapsulation Analysis Spectrometer Dimension Verification Dimension Verification Dimension Verification

Packaging

ESD Protection & Handling

All ESD-sensitive components are handled under anti-static control procedures.
Products are sealed in ESD-safe packaging to prevent electrostatic damage.
Proper labeling is applied for identification and traceability.
This ensures product integrity during storage, handling, and shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Delivery time
Deliverytime will need 2-4days to most of country all over the world for DHL/UPS/FEDEX/TNT.
Shipping fees reference DHL.
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(ReferenceDHL, Different Countries has different price.)

Shipment charges: (Reference DHL)
Weight(KG) Price(USD$)
0.00kg-1.00kg USD$60.00
1.00kg-2.00kg USD$70.00
2.00kg-3.00kg USD$80.00

More details: https://www.yic-electronics.com/shipment-way.htm
Please feel free contact us. Send any inquires or question toour Email Info@YIC-Electronics.com
We can do the best to you. Thank you very much your support.

Payment Way: Wire Transfer = Telegraphic Transfer(T/T) or PayPal or Western Union

Wire Transfer (T/T)

Our HSBC bank name: The Hongkong and Shanghai Banking Corporation Limited (HSBC Hong Kong)

Benefit Company Name: YIC International Co., Limited
Bank charges and payment account details, please click "Payment Way".

Western Union


Complete payment by Western Union.
Step 1. Go to your local Western Union branch, or go to their website (www.westernunion.com)
Step 2. Follow their instructions.


Bank charges and payment account details, please click "Payment Way".

PayPal Account:

PayPal Golden Key Supplier

PayPal Account:
PayPal Account ID: Info@YIC-Electronics.com
Company: YIC International Co., Limited

If you want to pay via Credit Card, please choose "Pay with my PayPal account" to continue by paypal.(www.paypal.com)
Bank charges details, please click "Payment Way".

User Review

  • Trac***

    I needed this Cyclone III FPGA for an older industrial interface board. The device accepted our existing configuration and the board passed its startup checks. Finding a compatible part saved us from redesigning the entire control section.

    October 12th, 2026

  • Driv***stemsDE

    This was purchased for servicing a large motor drive. After installation, switching waveforms looked normal and the unit completed our load test successfully. Packaging also protected the terminals well.

    September 21th, 2026

  • Bits***amBen

    Used the XC6SLX45 on a custom acquisition board with several parallel interfaces. Configuration was successful and the design has been running through overnight tests without errors.

    September 18th, 2026

  • Auto***rdRepair

    Exactly the MCU we needed for an automotive electronics repair. Programming and verification completed successfully, and the repaired controller has been stable on our test bench.

    September 10th, 2026

  • Powe***nch_NL

    This module went into a high-power inverter repair. Mounting and connections matched the original unit, and it handled our initial load tests without abnormal temperature rise. So far, very satisfied.

    September 1th, 2026

  • DCPo***Guru

    Designed a synchronous buck converter around this controller. Efficiency was impressive and voltage regulation remained very stable under changing loads.

    August 24th, 2026

  • Broa***stLab

    Used this crosspoint switch in a video distribution project. Signal integrity stayed excellent across every channel we tested.

    August 20th, 2026

  • Mich***Rowe

    Everything functions correctly and configuration was straightforward. I would have liked better protective packaging, but the device itself works perfectly.

    August 11th, 2026

  • Kevi***rshall

    Still a dependable MCU for maintaining older equipment. Programmed without problems and everything worked exactly like the original device.

    August 5th, 2026

  • Anal***uilder

    The DAC provides clean output and repeatable accuracy. Used it in a precision signal generation project with excellent results.

    July 28th, 2026

  • Etha***le

    I used this precision reference in a laboratory measurement board. Voltage stability was excellent, and drift stayed very low during several days of continuous testing. Definitely a quality analog component.

    July 22th, 2026

  • Sign***lockGuy

    Accurate crystal with stable frequency output. Worked perfectly as the timing source in a low-power embedded design.

    July 14th, 2026

  • Powe***idBuilder

    This hot-swap controller performed exactly as expected. Startup behavior was smooth and protection functions worked correctly during testing.

    July 6th, 2026

  • Yosh***_Engineer

    Used this instrumentation amplifier in a precision signal conditioning circuit. Low noise and stable gain characteristics made integration easy.

    July 2th, 2026

  • Taku***Ishikawa

    Used this IGBT module in a motor drive system. Power handling capability is impressive and the module remained reliable during repeated load testing.

    June 22th, 2026

  • Netw***Builder_UK

    Installed this Ethernet controller in a custom networking platform. Driver support was good and network communication remained stable during long-term testing.

    June 18th, 2026

  • Kent***orimoto

    Used this processor in a wireless networking project. Stable operation and good integration with existing software tools. Performance is sufficient for embedded communication applications.

    June 9th, 2026

  • Oliv***ughes

    Good capacitor quality. Used in a power supply rebuild and measured values were close to spec. No issues after several days of continuous operation.

    June 5th, 2026

  • Kevi***rner

    Very good MCU for legacy embedded projects. I used the LPC2387FBD100 in an industrial control board replacement and it integrated more smoothly than expected. Ethernet and peripheral support were enough for our needs. Been running continuously for over a week without instability.

    May 25th, 2026

  • Nath***ill

    Good supervisor IC for automotive power systems. Reliable reset behavior.

    May 19th, 2026

  • Jack***III

    Good price

    May 15th, 2026

  • Davi***ung

    Good SoC for networking applications. Stable signal processing and low power consumption.

    May 6th, 2026

  • Andr***ee

    Overall is good

    April 28th, 2026

  • Emil***ark

    Accurate frequency output for timing circuits. Works well in low-power signal designs.

    April 23th, 2026

  • Jose***Dong

    Quick response and clear answers.

    April 16th, 2026

  • Marc***echLab

    Excellent quality. All chips passed testing and showed consistent electrical characteristics.

    April 7th, 2026

  • Circ***MasterX

    Good packaging and fast shipping. Performance is stable, but I wish there was clearer labeling on each component.

    April 2th, 2026

  • SamT***Reviews

    Excellent ICs. Used them in a communication module and performance was stable.

    March 27th, 2026

  • Kevi***.

    Good quality parts. No failures during testing.

    March 17th, 2026

  • Bria***.

    Good

    March 13th, 2026

  • Mari***.

    Superb performance.

    March 2th, 2026

  • Emma***

    Excellent ICs for DIY projects. Came well-packaged, genuine parts, and all tested good on my bench. No fails on 50 pieces.

    February 26th, 2026

  • Gadg***an123

    Good

    February 10th, 2026

  • Quan***PartsLab

    Great service

    February 6th, 2026

  • Vect***upplyChain

    The sales rep was professional and responsive.

    January 27th, 2026

  • Puls***vePurchasing

    Components were packed carefully with anti-static protection and cushioning. Everything arrived in good condition.

    January 23th, 2026

  • Pixe***ocure

    Components were packed well. Appreciated the attention to detail.

    January 13th, 2026

  • Byte***dgeBuyer

    Good Quality & Fast Response

    January 5th, 2026

  • Circ***AtlasGlobal

    JUST WHAT I WANT

    December 30th, 2025

  • Allo***taImports

    Very professional

    December 26th, 2025

  • Apex***i

    Quick response and prompt shipping

    December 19th, 2025

  • Hexa***e Circuits

    We were surprised by how quickly our order was processed. From inquiry to delivery, everything was smooth. A trustworthy IC distributor with good stock levels.

    December 11th, 2025

  • Core***se Inc.

    Good customer service

    December 2th, 2025

  • Skyl***Drew

    Delivered ahead of schedule.

    November 28th, 2025

  • Byte***ad

    We purchased a batch of XC6SLX25T-2CSG324C from yic-electronics. Clean markings, fresh 2024 date codes, and antistatic packaging—service was efficient and polite.

    November 17th, 2025

  • avl_***rcing_julia

    Smooth checkout and same-day ship via FedEx. Parts arrived dry-packed, correct MSL labels, and fresh date codes.

    November 13th, 2025

  • Liam***hnson

    Price is good. Order processed quickly, and tracking provided the same night.

    November 3th, 2025

  • Yuko***kamura

    Prices were reasonable compared to other brokers. One reel had minor box damage, but the inner pack was intact.

    October 31th, 2025

  • Opti***

    Excellent prices and top-notch customer service. Even the standard shipping was surprisingly fast. Components were well-packed and genuine. Totally satisfied with the purchase.

    October 21th, 2025

  • Thom***Gray

    Clear communication and on-time delivery.

    October 15th, 2025

  • Aaro***ughes

    Excellent supplier. Great communication and reliable service throughout the process.

    October 9th, 2025

  • Auro***hip

    Good experience overall. The order was processed smoothly, packaging was secure, and the delivery time was acceptable.

    September 29th, 2025

  • Jimm***

    I had a great experience with this company. They were very professional and efficient, and they had the obsolete parts I needed in stock. Once payment was processed, the delivery was quick—my goods arrived within two weeks. The customer service was friendly professional, with seamless communication throughout. Overall, everything went smoothly, and I would definitely recommend them.

    September 19th, 2025

  • Jaso***in

    The purchase was easy and fast. Polite and helpful seller, great price.

    September 8th, 2025

  • NeoB***

    Schnelle Lieferung, Produkt entspricht der Beschreibung, hochwertige Verarbeitung, stabile Funktion, alles passt perfekt, sehr zufrieden mit dem Kauf.

    September 2th, 2025

  • Tobi***

    Quick response, good price and clear communication. Very satisfied with the service

    August 28th, 2025

  • Zóc***Nights

    Not bad

    August 19th, 2025

  • 3174***41@gmail.com

    Bought once to know that YIC electronic components quality is good, and the price is not expensive, very affordable, fast delivery!
    Really recommend buying electronic components here!

    April 14th, 2025

  • Yush***nagahata

    YIC is an excellent company.
    The deliverry time is fast, and we find it very usueful for procuring electronic components.
    We look forward to continuing our relationship in the future.
    Go YIC! Keep up the great work!

    February 20th, 2025

  • SAMI*** INSTALLATION

    Fantastic! Shure I would buy again with YIC

    January 23th, 2025

  • Aadh***x

    The experience with YIC International was great. They not only provided support for the proposed parts but also proactively suggested additional parts that could be useful for us. They have reviewed all the parts properly and corrected our requirements. The delivery and other logistical support were excellent.

    January 22th, 2025

  • Ke*

    A Reliable and Trustworthy Partner
    Received original, high-quality components with fast shipping from YIC electronics.

    November 25th, 2024

  • Nana***risnawan

    Great component supplier, a place that easy to find electronics parts at a good price and delivery.

    August 6th, 2024

  • Alge***n Gholson

    Great products, fast delivery.
    The quality and service of YIC Electronics' components are at the top of the industry. Highly recommended.

    February 20th, 2024

  • Frey***.

    Our partnership with YIC Electronics has been exceptionally satisfying. Their unwavering commitment to outstanding customer service, coupled with their highly competitive pricing and unwavering dedication to top-notch, high-performance product quality, has consistently impressed us. YIC Electronics stands out as a true industry leader in every aspect of their service. Their swift and efficient logistics feedback further underscores their professionalism and reliability.

    August 25th, 2023

  • Jo C***n

    High Quality Products!
    I received genuine, high-quality electronic parts. Thank you YIC electronics.

    August 12th, 2023

  • Edwa***W.

    Yic-electronics suppliers are top notch quality and consistent reliability, I have generated several orders from their website and their service has exceeded expectations in providing electronic components for our business needs.

    August 6th, 2023

  • Anna***

    Yic-electronics is a good partner for our company, we have been cooperating with each other for 4 years, and the cooperation is all smooth and there is no dispute about the goods. Our latest transaction with Yic-electronics happened a month ago, and the process was very smooth, thanks to Yic-electronics's help!

    June 17th, 2023

0 Articles

Post a Review

Hello , welcome to comment on this product
Rating *
5.0

Please limit the remark to 500 words

Your personal information will be hidden

FAQFrequently Asked Questions

  • What are the key design constraints when integrating the VI-2TZ-EX into a 48V distributed power architecture? The VI-2TZ-EX accepts input voltages from 66V to 160V, making it suitable for high-voltage bus architectures commonly found in telecom and data center power systems. When designing around the VI-2TZ-EX, ensure your input conditioning and upstream power distribution can maintain the converter within this window. At the lower bound (66V), verify that inrush current during startup does not cause excessive voltage sag on your primary bus. The converter's 15A output at 2V creates a 30W load at full capacity, so calculate your PCB trace width and thermal management accordingly, particularly in applications approaching the upper operating temperature of 85°C.
  • Can the VI-2TZ-EX replace a 3.3V isolated converter in a legacy ITE system, and what are the migration risks? The VI-2TZ-EX is specifically designed to output 2V, not 3.3V, so a direct replacement would require downstream voltage regulation or a different Vicor part number such as the VI-3.3TZ-EX if available for your input range. Migrating from a 3.3V converter to the VI-2TZ-EX would demand redesign of any circuits expecting 3.3V logic signaling or sensor interfaces. Additionally, verify that your replacement qualification includes re-characterization of thermal performance, as the VI-2TZ-EX's 88% efficiency and full-brick form factor may dissipate heat differently than your original converter. Contact Vicor's applications engineering to confirm pinout compatibility and control signal polarity before committing to the migration.
  • How does the VI-2TZ-EX's 3 kV isolation specification affect safety certification in multi-supply ITE applications? The 3 kV isolation rating of the VI-2TZ-EX provides galvanic separation between input and output, which is valuable in ITE designs where the converter bridges different voltage domains or grounds. When certifying the overall system to IEC 62368-1 or IEC 61010, the isolation voltage must be verified against creepage and clearance rules specific to your design. The 3 kV rating does not automatically satisfy functional safety or reinforced isolation requirements; your PCB layout must maintain appropriate spacing around the converter's isolation barrier. Consult your safety consultant early: if your system requires reinforced isolation (typically 4 kV minimum for some applications), the VI-2TZ-EX alone may not meet the requirement without additional isolation stages.
  • What thermal management strategy is necessary for the VI-2TZ-EX when operating continuously at full load in an enclosed chassis? The VI-2TZ-EX dissipates approximately 1.8W at full load (15A × 2V × (1 − 0.88 efficiency)) under nominal conditions. In an enclosed ITE chassis operating at the upper temperature limit (85°C ambient or junction), passive cooling via PCB copper planes and thermal vias may be insufficient. Thermal modeling should account for the converter's case temperature rising above ambient by the product of power dissipation and the thermal resistance from junction to case, then to the PCB. Many integrators use localized heatsinking, airflow ducting, or thermally conductive adhesive to direct heat away from the converter's underside. At 85°C, verify that no nearby components exceed their rated junction temperature and that solder joint reliability is maintained over the product lifetime (typically 10+ years for ITE applications).
  • Is the VI-2TZ-EX suitable for use in uncontrolled outdoor or industrial environments, or should it be limited to climate-controlled ITE facilities? The VI-2TZ-EX is rated for operating temperatures between −10°C and 85°C, which is typical for ITE equipment in climate-controlled data centers or indoor facilities. Use in uncontrolled outdoor or wide-temperature-range industrial environments would require external heating or cooling to keep the converter within its specified operating band. Additionally, the converter is labeled RoHS non-compliant, which may restrict its use in certain regulated markets or applications with strict environmental procurement standards. For long-term outdoor deployment, consider either temperature management measures or sourcing a RoHS-compliant alternative from Vicor's current portfolio. Moisture ingress and thermal cycling in outdoor settings can also degrade performance; consult Vicor's application notes for guidance on conformal coating or encapsulation strategies if industrial deployment is necessary.
  • How do the VI-2TZ-EX's over-current protection (OCP), over-temperature protection (OTP), and output voltage protection (OVP) features interact with load-dump or inrush events in the output stage? The VI-2TZ-EX incorporates OCP, OTP, OVP, and short-circuit protection (SCP) to defend against transient faults. When a load dump occurs—such as sudden disconnection of a 15A sink—the output voltage may spike unless a snubber or TVS diode limits overshoot. The OVP circuit will respond, but response time is finite; design the output snubber network to keep transient overshoot below the OVP threshold and minimize stress on downstream load circuits. Similarly, during startup, the VI-2TZ-EX's output slew rate and OCP threshold determine how quickly the converter can source current. If your application includes fast-switching loads or multiple parallel converters, coordinate the soft-start behavior across all supplies to prevent cascading OCP faults. Vicor's datasheet specifies protection thresholds; simulate or bench-test your load transients to confirm that protection activates safely without nuisance resets.
  • What is the typical input capacitance requirement for the VI-2TZ-EX to meet conducted EMI limits and maintain stable DC bus performance? The VI-2TZ-EX draws up to 15A on the 2V output side; the input-side current scales with the converter's input voltage and efficiency. At the upper input range (160V) with 88% efficiency, input current is approximately 0.1A; at the lower end (66V), input current rises to approximately 0.25A. Input capacitance and source impedance directly affect voltage ripple and EMI performance. Industry practice for isolated DC–DC converters in the VI-2TZ-EX's power class recommends 47µF to 100µF of ceramic or film capacitance within 10mm of the input pins, with additional bulk capacitance (≥470µF) distributed across the primary bus. Conduct measurements on a representative prototype to validate that input voltage ripple remains within acceptable bounds (typically ±5% for ITE applications) and that EMI compliance (FCC Part 15, CE EN 55011, etc.) is achieved. The full-brick form factor of the VI-2TZ-EX helps with integration, but tight input filtering is non-negotiable for system-level performance.
  • Can the VI-2TZ-EX be used in a paralleled configuration to achieve higher output current, and what are the inherent limitations? Paralleling multiple VI-2TZ-EX converters to sum the 15A outputs to reach, for example, 30A or 45A is technically feasible but requires careful control of current sharing. The VI-2TZ-EX is a voltage-mode converter; its 2V output is regulated independently. When two units are paralleled, load current distributes according to the output impedance of each converter and the interconnect resistance. Mismatches in output impedance or unequal component aging can cause one converter to carry disproportionate current, leading to thermal stress and premature failure. Many designs employ external current-sharing circuitry (such as low-value sense resistors and feedback controls) or exploit the 3 kV isolation of the VI-2TZ-EX to implement active current balancing. Alternatively, consider using a higher-power Vicor converter (such as the VI-4TZ or VI-6TZ if they exist in the 66V–160V input range) rather than paralleling. If paralleling is mandatory, validate thermal and electrical balance during qualification testing under the full range of input voltage, load, and ambient temperature conditions.
  • What lead times and obsolescence risks should be evaluated when designing the VI-2TZ-EX into a high-volume ITE platform? The VI-2TZ-EX is based on Vicor's VI-200™ series (75W class), which is an established, mature product line. However, lead times and supply availability are subject to market conditions and manufacturing capacity. For high-volume commitments (>10,000 units annually), engage Vicor's account management early to secure allocation and negotiate long-term pricing. The base product number is VI-2TZ; verify that Vicor's roadmap includes continued production of this variant or a pin-compatible successor. If obsolescence is a concern, request a second-source alternative or design in a compatible replacement (such as a different isolated converter with the same electrical interface) in parallel. Document your long-term requirements in design reviews and ensure that supply-chain risk is flagged to procurement and product management before entering high-volume production.
  • How does the VI-2TZ-EX's full-brick package and 0.50" height impact PCB layout, thermal routing, and mechanical reliability in confined chassis designs? The VI-2TZ-EX measures 4.60" L × 2.40" W × 0.50" H (116.8mm × 61.0mm × 12.7mm), making it relatively compact for a 15W isolated converter but still substantial in applications with aggressive space constraints. The full-brick form factor facilitates mounting on standard PCB-mounted stands or thermal interfaces. However, the 0.50" height leaves minimal clearance above the converter if the PCB is enclosed by a shield or secondary daughter card. Thermal vias and copper-pour areas beneath the converter must be unobstructed to dissipate the ~1.8W of internal loss. Route input and output traces on inner layers where possible to avoid interference with mechanical structures and to minimize loop inductance. If your chassis design requires multiple layers of PCBs or tight vertical stacking, simulate thermal and mechanical performance early to avoid costly redesigns. Verify that the through-hole or surface-mount footprint of the VI-2TZ-EX (consult the specific datasheet for pinout details) is compatible with your board thickness and assembly process.
  • What input voltage conditioning is necessary before the VI-2TZ-EX to protect against transient overvoltage from upstream switching or faults? The VI-2TZ-EX specifies a maximum input voltage of 160V. Transients on the input bus—caused by switching of upstream regulators, load-dump events, or distribution faults—can exceed this limit and damage the converter. A series diode, clamping circuit, or TVS array rated for at least 160V + 20% margin (192V typical) should be placed directly at the input connector or as close as practical to the VI-2TZ-EX. Many ITE designs employ a transient suppressor array (e.g., multi-line TVS devices rated for 48V–400V systems) to protect multiple converters in parallel. Simulate or bench-test the input transient response (using a function generator or arbitrary waveform generator to inject 200V, 500ns pulses, for example) to confirm that the clamping device operates within its energy rating and that the VI-2TZ-EX's input protection circuits do not trigger nuisance faults. Documentation of transient withstand testing is valuable for design reviews and field troubleshooting.
  • Is the VI-2TZ-EX RoHS compliance status a barrier to design-in for regulated OEM customers, and what are the alternatives? The VI-2TZ-EX is explicitly marked as RoHS non-compliant. Many OEM customers—particularly in the EU, Asia, and regulated markets—mandate RoHS compliance for all components entering production, regardless of exemptions. If your customer requires RoHS compliance, the VI-2TZ-EX cannot be used without a formal exemption or substitution. Contact Vicor to determine if a RoHS-compliant variant (such as VI-2TZ with a different suffix) exists or if an alternative part from Vicor's current portfolio is available for the 66V–160V input range at 2V output. If no compliant replacement is available in Vicor's lineup, begin evaluation of alternative suppliers (such as Murata, TDK, or Vicor's competitors in the isolated DC–DC market). Note that switching to an alternative requires re-qualification of thermal, electrical, and mechanical performance; allow adequate schedule buffer in your product development timeline for this substitution.
  • How should the VI-2TZ-EX's output sense line be routed to ensure accurate 2V regulation under transient load conditions? The VI-2TZ-EX regulates its 2V output via an internal feedback network. In isolated converters, the output voltage sense line is typically carried across the isolation barrier; precise routing of this sense trace is critical to avoid capacitive coupling from the high-frequency switching node, which can inject noise and degrade DC accuracy. Route the sense line (typically labeled Vout+ or Vout−) as a twisted pair with its return, kept away from high-current traces and switching nodes on the PCB. If the sense line travels more than 6 inches from the converter, consider shielding it to reduce external interference. Additionally, verify that the sense point is taken at the load connector or at a remote point where regulation is actually needed, rather than at the converter PCB pad, to account for distribution losses in the interconnect. This is particularly important if multiple converters feed a shared 2V bus; remote sensing on the VI-2TZ-EX helps prevent circulating currents and voltage imbalance among paralleled units.
  • What is the recommended procedure for safe removal and replacement of a faulty VI-2TZ-EX in a live chassis, and are there any hold-up time or energy release hazards? The VI-2TZ-EX does not incorporate a built-in hold-up capacitor or energy storage on the output side; however, bulk capacitance on the 2V output bus (if present for filtering or paralleling) stores energy. Before removing a VI-2TZ-EX from a live system or energized PCB, discharge the output rail through a resistor or shorting probe to eliminate any stored charge and prevent arcing or damage to downstream circuits. The isolated input is typically safe (the input is not referenced to the output ground), but confirm with your system design that no hazardous potentials exist. After removal, inspect the converter pins for corrosion, solder joint quality, or visible damage; if the VI-2TZ-EX failed due to external fault (overvoltage, short circuit, or thermal runaway), diagnose and correct the root cause before installing a replacement. Replace the converter at the same time as addressing the fault condition (e.g., repair the transient protection circuit, improve input filtering, or enhance thermal management) to prevent premature failure of the replacement unit.
  • Under what load and temperature conditions does the VI-2TZ-EX reach its 88% efficiency peak, and how does efficiency vary across the operating range? The VI-2TZ-EX is rated at 88% efficiency, but this figure typically corresponds to nominal or near-rated operating conditions—often at full 15A output, mid-range input voltage (around 100V), and moderate ambient temperature (approximately 25°C to 50°C). As load current decreases, converter switching losses become a larger proportion of output power, so efficiency may drop at very light loads (e.g., below 20% of rated current). Conversely, at high ambient temperatures (approaching 85°C) or extreme input voltages (66V or 160V), internal resistive and switching losses increase, potentially reducing efficiency by 1–3 percentage points. For accurate power budget calculations in your application, consult the VI-2TZ-EX datasheet for an efficiency curve or request efficiency data from Vicor at your specific operating point. If your system operates predominantly at light load or experiences wide temperature swings, perform a thermal sensitivity analysis to verify that the converter remains within acceptable junction-temperature limits. Applications with strict efficiency requirements (>90%) or strict thermal budgets may need to reconsider the input voltage level or load architecture to optimize VI-2TZ-EX performance.
  • Can the VI-2TZ-EX be used in a battery backup or uninterruptible power supply (UPS) application with variable input voltage from 66V to 160V? The VI-2TZ-EX is designed for continuous operation across the 66V–160V input range, making it compatible with UPS and backup power architectures where the input bus voltage is maintained by battery-to-converter switching or boost/buck regulation. However, verify that your UPS input conditioning does not introduce transients or dips below 66V during switchover events, as the converter may reset or latch off if the input falls below the minimum threshold. Additionally, in a UPS context, the load (typically a server, network equipment, or storage system) may demand high current peaks during restart after power loss; ensure that the VI-2TZ-EX's 15A output capability and over-current protection settings are compatible with your load's soft-start profile. If the UPS application requires fail-safe output (e.g., forced 2V regulation even if the primary input is lost), design an auxiliary power path or secondary converter to maintain the 2V rail during transitions. Test the complete UPS failover and restart sequence on a representative VI-2TZ-EX prototype to validate that the converter does not exhibit latch-up, false trips, or delayed startup under transient conditions.
  • What is the relationship between the VI-2TZ-EX's 15W power rating and its continuous thermal dissipation capability in different mounting configurations? The VI-2TZ-EX is rated at 15W, which describes its output power (2V × 15A) under ideal conditions. Internal dissipation at full load is approximately 1.8W (as calculated from 15W / 0.88 efficiency), but this dissipation becomes heat that must be removed from the junction to the ambient. The thermal resistance from junction to case (Rθ-jc) and case to ambient (Rθ-ca) determine how high the junction temperature rises above ambient. The full-brick package typically has Rθ-jc in the range of 10–20 K/W; PCB copper area, thermal vias, and any external heatsink reduce Rθ-ca. At 85°C ambient and 1.8W dissipation, a typical board layout might yield a case temperature around 90–100°C, which could exceed the converter's rated junction limit if margins are not sufficient. Consider using a thermal interface material (TIM), aluminum spacer, or direct contact between the converter case and a heatsink to reduce thermal resistance. For long-term reliability (MTBF), maintain the junction temperature well below 125°C (a common industry de-rating threshold). Run thermal measurements on your first prototype to validate the design, particularly if the final production chassis deviates significantly from the development platform.
  • How do the VI-2TZ-EX's SCP (short-circuit protection) and OCP features respond to a hard short on the 2V output, and what is the time-to-shutdown behavior? When a hard short-circuit occurs on the 2V output of the VI-2TZ-EX, the SCP circuit detects excessive current (typically 120–150% of nominal 15A) and initiates a shutdown sequence. The converter does not source unlimited current; instead, it limits output current and then latches off to prevent damage to the power stage. The time-to-shutdown is typically in the microsecond range, but the exact response depends on the converter's internal current-sense threshold and latch-off logic. During the fault condition, the 2V output collapses toward zero, and the converter draws quiescent current from the input. If the short persists (e.g., a solder bridge or failed component on the load side), the VI-2TZ-EX remains latched off until either the fault is cleared or the input is cycled (power cycle). To recover from a latched-off state after a transient short, cycle the input power by toggling the upstream supply or using a soft-start/enable line if available. In system design, use fusing or circuit-breaker coordination to ensure that a localized short on the 2V rail does not cascade to other converters on the same primary bus; consider designing the output distribution such that each converter is separately fused and monitored for fault isolation.
  • What is the expected lifespan and mean time between failure (MTBF) of the VI-2TZ-EX in continuous operation at rated load and temperature, and how can this be estimated for specific applications? Vicor typically publishes MTBF estimates for the VI-200™ series (of which the VI-2TZ-EX is a member) using standard reliability models such as Telcordia (SR-332) or MIL-HDBK-217. The MTBF is heavily dependent on junction temperature and operating stress (voltage, current, duty cycle). At elevated junction temperatures (approaching 125°C), MTBF may be significantly lower than at moderate temperatures (50–70°C). For a 2V, 15A isolated converter operating at nominal conditions in a temperature-controlled ITE environment, an MTBF of 1–2 million hours is not uncommon, translating to a design life of 10–20 years for a single unit at steady-state operation. However, if the VI-2TZ-EX operates in a high-temperature or high-stress environment (e.g., 85°C ambient plus internal dissipation), or if thermal cycling occurs due to intermittent load or seasonal variations, the MTBF can be reduced by 30–50%. Consult Vicor's reliability data sheet or use their MTBF calculator (if available) to estimate a specific MTBF for your application profile. In mission-critical systems, design in redundancy or planned component replacement intervals based on your calculated MTBF and acceptable risk tolerance.
  • Does the VI-2TZ-EX require a soft-start or current ramp circuit to prevent inrush damage to downstream logic when power is first applied? The VI-2TZ-EX is an isolated converter with internal regulation; its 2V output does not slew instantaneously to the final voltage upon input power application. Instead, the converter's control loop and internal soft-start circuitry typically ramp the output voltage over a period of milliseconds (typically 10–50ms, depending on the design). This natural soft-start behavior protects downstream logic and memory devices from voltage overshoot and reduces inrush current stress on the input supply. However, if your application includes low-impedance loads (such as bulk bypass capacitance on the 2V rail) or requires an even gentler ramp to meet specific system startup requirements, an external RC network or active soft-start circuit can be added to the enable or feedback signal of the VI-2TZ-EX (if such a signal is available on the specific pinout). Consult the VI-2TZ-EX pinout and control schematic in the datasheet to determine whether an external enable input or feedback network is provided. If the converter provides a feedback or enable pin, coordinate its ramp time with your upstream power supply and system startup sequence to ensure that all rails come up in the correct order and at compatible rates, preventing latch-up or reset of sensitive ICs.