Hello Guest

Sign in / Register

Welcome,{$name}!

/ Logout
English
EnglishDeutschItaliaFrançais한국의русскийSvenskaNederlandespañolPortuguêspolski繁体中文SuomiGaeilgeSlovenskáSlovenijaČeštinaMelayuMagyarországHrvatskaDanskromânescIndonesiaΕλλάδαБългарски езикGalegolietuviųMaoriRepublika e ShqipërisëالعربيةአማርኛAzərbaycanEesti VabariikEuskeraБеларусьLëtzebuergeschAyitiAfrikaansBosnaíslenskaCambodiaမြန်မာМонголулсМакедонскиmalaɡasʲພາສາລາວKurdîსაქართველოIsiXhosaفارسیisiZuluPilipinoසිංහලTürk diliTiếng ViệtहिंदीТоҷикӣاردوภาษาไทยO'zbekKongeriketবাংলা ভাষারChicheŵaSamoaSesothoCрпскиKiswahiliУкраїнаनेपालीעִבְרִיתپښتوКыргыз тилиҚазақшаCatalàCorsaLatviešuHausaગુજરાતીಕನ್ನಡkannaḍaमराठी
Home > Blog > Inductors in Series: Formulas, Mutual Inductance, and Examples

Inductors in Series: Formulas, Mutual Inductance, and Examples

Inductors in series share the same current, while their equivalent inductance depends on the magnetic interaction between their windings. Separate components are not necessarily magnetically uncoupled. This article explains the series formulas, winding polarity, worked calculations, and measurement checks.

Catalog

1. Inductors in Series: Circuit Connection and Current
2. Total Inductance of Uncoupled Series Inductors
3. Mutual Inductance Between Series Inductors
4. Series-Aiding and Series-Opposing Inductors
5. Calculating Total Inductance With Mutual Coupling
6. Inductors in Series: Formula Comparison
7. Common Mistakes and Measurement Checks
8. Conclusion

Inductors in Series

Inductors in Series: Circuit Connection and Current

Inductors are connected in series when they form a single continuous current path with no branches between them. In Figure 2, current entering terminal A passes through all three windings before reaching B, while the marked voltage polarities follow the passive sign convention.

Three Uncoupled Inductors in Series

i(t) = iL1(t) = iL2(t) = iL3(t)

i(t) is the instantaneous series current, in amperes (A).

iL1(t), iL2(t), and iL3(t) denote the currents through the individual inductors, also in amperes.

If the current changes, each inductor experiences the same rate of current change, di/dt. However, the voltage across each inductor depends on its inductance and, where applicable, its magnetic coupling with other inductors.

Total Inductance of Uncoupled Series Inductors

For linear inductors with negligible mutual coupling, the equivalent inductance equals the sum of the individual inductances. The derivation below assumes constant inductances and operation where winding resistance and parasitic capacitance can be neglected.

Kirchhoff's Voltage Law (KVL) provides the basis for deriving the equivalent inductance.

For three series inductors, Kirchhoff’s Voltage Law gives:

vT = v1 + v2 + v3

vT is the total terminal voltage, and v1, v2, and v3 are individual winding voltages, all in volts (V).

Each voltage is referenced using the passive sign convention, with current entering the terminal marked positive.

For an ideal linear inductor:

v = L didt

v is the instantaneous voltage across the inductor, in volts.

L is the inductance, in henries.

di/dt is the rate of current change, in amperes per second.

Series Inductance Formula

Substituting the ideal inductor voltage relation into the voltage sum and collecting the common current derivative gives the following result for N uncoupled inductors:

LT = L1 + L2 + ⋯ + LN

LT is the total equivalent inductance, in henries (H).

L1 through LN are the individual inductances, in henries.

N is the number of series-connected inductors.

All inductance values must use consistent units before addition. For example, 1 H equals 1,000 mH, while 1 mH equals 1,000 µH.

For positive-valued, uncoupled inductors, the total inductance is greater than the inductance of any individual component. This conclusion does not automatically apply to magnetically coupled inductors, where opposing magnetic coupling may reduce the equivalent inductance.

Actual winding resistance, parasitic capacitance, and magnetic nonlinearity limit the ideal model. Nominal inductance alone does not describe behavior over every current or frequency range.

Series Inductance Calculation Example

Calculated Example 1. Three uncoupled, linear inductors have values of 10 mH, 40 mH, and 50 mH. Their ideal equivalent inductance is:

LT = 10 mH + 40 mH + 50 mH = 100 mH

The result does not establish the assembly's current rating, DC resistance, or frequency response. Those characteristics depend on the actual components and their operating conditions.

AC Impedance and Self-Resonance

For an ideal linear series combination, the inductive impedance is:

ZL = j2πfLT

At a fixed frequency, a larger total inductance therefore produces a larger inductive reactance magnitude. This ideal relation is useful only while winding resistance and parasitic capacitance are small enough that the assembly still behaves predominantly as an inductor.

As frequency approaches self-resonance, parasitic capacitance increasingly affects the terminal impedance, and the simple inductive model becomes inaccurate. The usable frequency range therefore depends on the actual inductors and their parasitic characteristics.

Mutual Inductance Between Series Inductors

Mutual inductance occurs when a changing current in one inductor produces magnetic flux that links another inductor and induces a voltage in its winding.

Inductors placed close together may exhibit magnetic coupling, particularly when their windings share a magnetic core or are arranged so that their magnetic fields overlap.

The amount of coupling depends on the magnetic path, winding geometry, relative orientation, and core properties. Physical distance alone does not determine whether coupling is negligible.

Published Measurement Example. Analog Devices AN-2592 reports third-party measurements from a specific two-inductor test arrangement using two 8.3 mH inductors in a series-aiding configuration. The measured combined inductance was 25.8 mH at 1 mm separation, 19.3 mH at 10 mm separation, and approximately 16.6 mH at 100 mm separation. These values demonstrate how coupling changed in that particular geometry and orientation; they are not universal distance-dependent inductance values and are not original measurements from this article.

For two passive, linear, reciprocal coupled windings, the mutual inductance magnitude M is related to the coupling coefficient by:

M = k √(L1 L2)

M is the magnitude of mutual inductance, in henries.

k is the dimensionless magnetic coupling coefficient.

L1 and L2 are the self-inductances of the individual windings.

0 ≤ k ≤ 1

Here, zero indicates no coupling and one represents ideal perfect coupling. The corresponding limit on M provides a consistency check:

0 ≤ M ≤ √(L1 L2)

A mutual inductance magnitude above this limit is inconsistent with the passive linear model. The sign used in the series formula is determined separately by winding polarity.

Series-Aiding and Series-Opposing Inductors

Coupled windings can be connected so that their mutual voltage contributions reinforce or oppose the self-inductive contributions. These connections are called series-aiding and series-opposing, respectively.

Dots mark corresponding winding polarity terminals. When current referenced into one dotted terminal is increasing, its mutual contribution makes the other dotted terminal positive relative to the undotted terminal. When that current decreases, the induced polarity reverses. A steady current produces no mutual voltage in this ideal model.

The same series current enters both dotted terminals, or leaves both, for an aiding connection. It enters one dot and leaves the other for an opposing connection. Check the manufacturer’s winding diagram because a package dot may simply identify pin 1.

Series-Aiding Inductors

Figure 3 shows current entering the dotted terminal of each winding. With nonzero coupling, the two mutual voltage contributions add, increasing the equivalent inductance above the sum of the self-inductances.

Series-Aiding Coupled Inductors.

For two linear coupled windings, the equivalent inductance is:

LT = L1 + L2 + 2M

Series-Opposing Inductors

Figure 4 shows current entering the dot of the first winding and leaving the dot of the second. The mutual contributions subtract from the self-inductive contributions.

Series-Opposing Coupled Inductors.

The equivalent inductance is:

LT = L1 + L2 − 2M

All inductances in these equations are in henries, and M is a nonnegative magnitude. For identical ideal windings with perfect coupling, L1 = L2 = L and M = L:

LT = L + L − 2L = 0

This is an ideal limiting result, not a claim that physical series-opposing windings have exactly zero inductance.

Real assemblies may retain leakage inductance because magnetic coupling is not perfect. Their measured impedance also includes nonideal electrical characteristics.

For unequal self-inductances, even perfect coupling generally leaves a positive equivalent inductance. Reversing the connections of one winding changes aiding to opposing while preserving the series current path.

Calculating Total Inductance With Mutual Coupling

For two linear reciprocal windings carrying the same series current, each winding voltage contains its self-inductive contribution and one mutual-voltage contribution:

v1 = (L1 ± M) didt

v2 = (L2 ± M) didt

The plus signs apply to the series-aiding connection and the minus signs to the series-opposing connection, using the dot convention and passive voltage references defined in C4. Under the assumed linear reciprocal model, adding the two winding voltages gives:

vT = v1 + v2 = (L1 + L2 ± 2M) didt

The two mutual contributions combine as ±M ± M = ±2M, which produces the equivalent-inductance expressions given in C4. These relations assume constant inductance parameters in a linear reciprocal model and do not describe a saturated core or operation near self-resonance.

Series-Aiding Inductance Calculation

Calculated Example 2. Two linear windings each have a self-inductance of 10 mH and mutual inductance magnitude of 5 mH. In series-aiding polarity:

LT = 10 mH + 10 mH + 2 × 5 mH = 30 mH

The coupling coefficient is dimensionless and within the permitted range:

k = 5 mH√((10 mH)(10 mH)) = 0.5

Reversing one winding, while retaining the geometry and the same inductance parameters, gives:

LT = 10 mH + 10 mH − 2 × 5 mH = 10 mH

Finding Mutual Inductance From Total Inductance

Calculated Example 3. Two linear coils have self-inductances of 20 mH and 60 mH, and a specified series-aiding equivalent inductance of 100 mH. Rearranging the aiding formula gives:

M = (LT − L1 − L2)2

M = (100 mH − 20 mH − 60 mH)2 = 10 mH

The consistency check gives:

k = 10 mH√((20 mH)(60 mH)) ≈ 0.289

Inductors in Series: Formula Comparison

Use the connection type, coupling assumption, and dot convention to select the applicable expression. The coupled-winding rows assume two linear reciprocal windings, with M defined as a nonnegative magnitude.

Connection Type
Equivalent Inductance
Applicable Conditions or Dot Rule
Uncoupled Series

LT = Σi = 1N Li

Mutual coupling is negligible; use the individual inductances under the stated operating conditions.
Series-Aiding

LT = L1 + L2 + 2M

Two coupled windings; the series current enters both dotted terminals or leaves both dotted terminals.
Series-Opposing

LT = L1 + L2 − 2M

Two coupled windings; the series current enters one dotted terminal and leaves the other.
Multiple Coupled Windings
Case-specific
Include the signed pairwise mutual-inductance terms for the coupled winding pairs; do not extend the two-winding ±2M formula directly.

Common Mistakes and Measurement Checks

Before comparing calculations with measurements, verify the winding polarity and the assumed coupling. Adding nominal values ignores mutual inductance, and choosing the wrong sign reverses its effect.

• Inconsistent units: Combining henries, millihenries, and microhenries without conversion produces incorrect results.

• Unspecified measurement frequency: Physical inductors may show different measured equivalent inductance at different test frequencies.

• Core nonlinearity: Magnetic-core inductance may change with current, particularly as the core approaches saturation.

• Component tolerances: Nominal inductance values are not exact measured values.

• Parasitic effects: Winding resistance, capacitance, and fixture impedance can affect instrument readings.

Check the component datasheets for test conditions, tolerance, DC resistance, thermal current limits, and saturation characteristics. Thermal and saturation ratings describe different limits. For coupled windings, the connection and combined core excitation also matter.

Current Ratings and Copper Losses of Series Inductors

Because the same current flows through every series element, each inductor must independently satisfy its applicable thermal current rating at the expected RMS current and its peak-current or saturation requirement at the maximum instantaneous current. Thermal and saturation limits are different constraints and should be checked using the manufacturer’s stated test conditions.

For two series inductors at low frequency, where additional AC winding loss and core loss are not significant, the combined copper loss can be approximated as:

Pcu ≈ Irms2(RDC1 + RDC2)

The DC winding resistances add in series because the same current passes through both windings. The higher combined DC resistance increases voltage drop and resistive heating for a given current, so use manufacturer-specified DC resistance values and their applicable temperature conditions. At higher frequency, skin effect, proximity effect, and core loss can make total loss exceed this simple I²R approximation.

Measuring With an LCR Meter

An LCR meter can measure the equivalent inductance of a series-connected assembly under controlled test conditions.

The Keysight E4980B operates from 20 Hz to 2 MHz. E4980BL variants operate from 20 Hz to 300 kHz (E4980BL-032), 500 kHz (E4980BL-052), or 1 MHz (E4980BL-102). Select a test frequency that is appropriate to the inductor and to the comparison being made.

The instrument supports both series-equivalent and parallel-equivalent inductance modes. Ls and Lp represent different equivalent loss models for the measured impedance, so select the mode according to the component impedance, the manufacturer’s stated test method, and the intended comparison rather than always requiring Ls.

Before testing, disconnect external power, safely discharge stored energy, and isolate the components from circuit paths that could influence the reading.

1. Record the nominal inductances, tolerances, test frequencies, and winding polarity information.

2. Select the test frequency, signal level, equivalent-circuit mode, and any DC bias appropriate to the comparison. Keep these settings consistent.

3. Perform the fixture compensation specified by the instrument manufacturer.

4. Measure each winding separately, leaving the other winding open-circuit. Keep the physical arrangement unchanged when investigating coupled coils.

5. Measure the series connection at the same settings. For negligible coupling, compare it with the sum of the separately measured inductances.

6. For intentional coupling, measure both aiding and opposing connections without moving the coils. Avoid a test level that changes their magnetic operating point.

For linear reciprocal windings with unchanged parameters, subtracting the opposing inductance from the aiding inductance cancels the self-inductance terms. The mutual inductance magnitude can therefore be estimated by:

M = (Laiding − Lopposing)4

Laiding and Lopposing are the measured equivalent inductances, in henries. This estimate assumes comparable measurement conditions, negligible parasitic influence, and unchanged winding parameters. A disagreement with the ideal model can reflect fixture errors, losses, frequency dependence, or core nonlinearity rather than a failed component.

Conclusion

Inductors connected in series share the same current, but their equivalent inductance depends on the magnetic interaction between their windings. For uncoupled inductors, the individual inductances add directly, while coupled inductors require a positive or negative mutual-inductance term according to winding polarity. Accurate calculations therefore depend on identifying magnetic coupling, applying the correct connection formula, and checking that the assumed component behavior matches the intended operating or measurement conditions.






Frequently Asked Questions [FAQ]

1. Can Inductors With Different Current Ratings Be Connected in Series?

Yes, if every component meets the application’s thermal and magnetic operating limits. For coupled windings, also check the manufacturer’s connection-dependent limits and core excitation. A larger rating on one component does not increase the rating of the others.

2. Does Reversing an Uncoupled Inductor Change the Total Inductance?

No. Reversing the terminals of an ideal two-terminal inductor does not change its self-inductance or the total inductance of an uncoupled series connection. Winding orientation becomes relevant when magnetic coupling exists between components.

3. What Happens if One Inductor in a Series Circuit Becomes Open-Circuit?

An open winding interrupts the entire series current path. Under steady DC conditions, no current can flow through the disconnected path, although stored magnetic energy and switching transients must be considered when the failure occurs. A continuity measurement on a safely disconnected circuit can help identify the affected component.

4. Can Series-Connected Inductors Replace a Single Inductor in a Filter Circuit?

They can provide a required equivalent inductance when their combined impedance and operating characteristics suit the filter design. However, the replacement may have different winding resistance, parasitic capacitance, current capability, and frequency response. These characteristics should be checked against the filter requirements and applicable component datasheets.

Related Blog